(At the
controller & devices)
(At the cable)
50 PIN CENTRONICS FEMALE at the controller & devices.
50 PIN CENTRONICS MALE at the cable.
Pin | Name | Dir | Description |
---|---|---|---|
01 | GND | ![]() |
Ground |
02 | +DB0 | ![]() |
+Data Bus 0 |
03 | +DB1 | ![]() |
+Data Bus 1 |
04 | +DB2 | ![]() |
+Data Bus 2 |
05 | +DB3 | ![]() |
+Data Bus 3 |
06 | +DB4 | ![]() |
+Data Bus 4 |
07 | +DB5 | ![]() |
+Data Bus 5 |
08 | +DB6 | ![]() |
+Data Bus 6 |
09 | +DB7 | ![]() |
+Data Bus 7 |
10 | +DBP | ![]() |
+Data Bus Parity (odd Parity) |
11 | DIFFSENS | ? | ??? |
12 | res | - | Reserved |
13 | TERMPWR | ![]() |
Termination Power |
14 | res | - | Reserved |
15 | +ATN | ![]() |
+Attention |
16 | GND | ![]() |
Ground |
17 | +BSY | ![]() |
+Bus is busy |
18 | +ACK | ![]() |
+Acknowledge |
19 | +RST | ![]() |
+Reset |
20 | +MSG | ![]() |
+Message |
21 | +SEL | ![]() |
+Select |
22 | +C/D | ![]() |
+Control or Data |
23 | +REQ | ![]() |
+Request |
24 | +I/O | ![]() |
+In/Out |
25 | GND | ![]() |
Ground |
26 | GND | ![]() |
Ground |
27 | -DB0 | ![]() |
-Data Bus 0 |
28 | -DB1 | ![]() |
-Data Bus 1 |
29 | -DB2 | ![]() |
-Data Bus 2 |
30 | -DB3 | ![]() |
-Data Bus 3 |
31 | -DB4 | ![]() |
-Data Bus 4 |
32 | -DB5 | ![]() |
-Data Bus 5 |
33 | -DB6 | ![]() |
-Data Bus 6 |
34 | -DB7 | ![]() |
-Data Bus Parity7 |
35 | -DBP | ![]() |
-Data Bus Parity (odd Parity) |
36 | GND | ![]() |
Ground |
37 | res | - | Reserved |
38 | TERMPWR | ![]() |
Termination Power |
39 | res | - | Reserved |
40 | -ATN | ![]() |
-Attention |
41 | GND | ![]() |
Ground |
42 | -BSY | ![]() |
-Bus is busy |
43 | -ACK | ![]() |
-Acknowledge |
44 | -RST | ![]() |
-Reset |
45 | -MSG | ![]() |
-Message |
46 | -SEL | ![]() |
-Select |
47 | -C/D | ![]() |
-Control or Data |
48 | -REQ | ![]() |
-Request |
49 | -I/O | ![]() |
-In/Out |
50 | GND | ![]() |
Ground |